ELECTRIC INVERTER,S ACCELERATION TIME AND DECELERATION TIME ( C 1~01 TO 08)




C 1 ~01  ACCELERATION TIME 1:

it defines the acceleration time from 0% to 100% of the max output frequency . the unit in second.

C 1~02  DECELERATION TIME 1:

it defines the deceleration time from 0% to 100%of the max output frequency . the unit is second .

C 1~03 ACCELERATION TIME 2:

the acceleration time when the acceleration / deceleration time option 1 is set as on .

C 1~04 DECELERATION TIME 2:

it defines the deceleration time when the acceleration / deceleration time option 1 is on.

C 1~05 ACCELERATION TIME 3:

it defines the acceleration time when the acceleration / deceleration time option 2 is on.

C 1~06 DECELERATION TIME 3:

it defines the deceleration time when the acceleration / deceleration time option 2 is on.

C 1~07 ACCELERATION TIME 4:

it defines the acceleration time when acceleration / deceleration time option 1 is and acceleration /deceleration time option 2 are both on.

C 1~08 DECELERATION TIME 4:

it defines the deceleration time when acceleration / deceleration  time option 1 and acceleration / deceleration time option 2 are both on.

it defines the deceleration time when acceleration/ deceleration time option 1 and acceleration / deceleration time option 2 are both on.

NOTE:
please set the acceleration time and deceleration time respectively . acceleration time to set the time from the 0% to 100% of the max output frequency . deceleration time to set the time from o% to 100%of the max output frequency . acceleration can be set four types , 1~ 4 in the situation using acceleration and deceleration time 2~4 please set acceleration and deceleration time option 1 and set acceleration and deceleration time 2 in multi function inputs  (h 1~01 ,~h 1~06) . the setting range depends on setting value  c 1-10 (acceleration/ deceleration times unit),the above table is factory default value . when c 1~10,s setting is "0"(in unit of 0.01)the setting range is 0.00- 600.00 seconds..