PID OUTPUT CHARACTERISTICS SELECTION AND PID OUTPUT GAIN AND PID REVERSE OUTPUT SELECTION OF INVERTER

PID OUTPUT CHARACTERISTICS SELECTION.


the forward/reverse  characteristics selection of pid output 0: the forward operation characteristics of pid output  1:the reverse operation characteristics of pid output (output symbol is for reverse operation )

PID OUTPUT GAIN.

it is used to set the output gain of pid.
note :the contact to adjust the gain of pid control : setting range 0.0~25.0 frequency setting is 1.0

PID REVERSE  OUTPUT SELECTION :

it is the reverse operation selection of pid output. 0:executes 0 limit if pid output is negative  (dose not revers ). 1: reverse rotation if pid output is negative .
note : reverse operation will not act if revise prohibition is selected in   b 1-04 . setting range is 0~1
factory setting is 0 .