ELECTRIC INVERTER,S PID REVERSE OUTPUT SELECTION, SELECTION OF PID FEEDBACK COMMAND LOSS DETECTION AND PID FEEDBACK COMMAND LOSS DETECTION LEVEL



PID REVERSE OUTPUT SELECTION.

it is the reverse operation selection of pid output . 0: executes  0 limit if pid output is negative (dose not reverse ). 1:reverse rotation if pid output is negative .
note : reverse operation will not act if revise prohibition is selected in   b 1 -04 .

SELECTION OF PID FEEDBACK COMMAND LOSS DETECTION .

0:no detection of feedback loss . 1: pid feedback loss detection is available . to continue to operate after the detection ,but the abnormal contact will not act . 2: pid feedback command loss detection is available . to coast to stop after the detection and the abnormal contact will act .

PID FEEDBACK COMMAND LOSS DETECTION LEVEL.

it is used to set the pid feedback loss detection level in unit of %with max . output frequency taken as 100 % . setting range is 0~100, frequency setting is  0  . change during operation is  x  .
control methods .
v/f is a .
v/f with   p g  is a.
open loop vector  is  a.
flux vector is  a.