AC/DC INVERTER,S HUNTING PREVENTION SELECTION,AND HUNTING PREVENTION GAIN.




HUNTING PREVENTION SELECTION.
 0:DISABLED
1:ENABLED

NOTE:   THE HUNTING PREVENTION FUNCTION IS USED TO STOP A MOTOR UNDER A LIGHT LOAD FROM HUNTING . THIS FUNCTION IS EXCLUSIVELY  FOR  THE  V/F  CONTROL  MODE, WHEN  GREATER RESPONSIVENESS THAN OSCILLATION CONTROL IS  REQUIRED SET HUNTING PREVENTION TO ,DISABLED
.
 HUNTING PREVENTION GAIN.

SETS THE RATIO FOR HUNTING  PREVENTION GAIN.

NOTE:  INCREASE THE SETTING IN  C 7-0 2 OSCILLATION OCCURS WHEN OPERATING  WITH A LIGHT LOAD . (IF THE SETTING IS INCREASED TOO MUCH , THE CURRENT CAN FALL TO THE POINT WHERE STALLING OCCURS,). DECREASE THE SETTING IN        C 7-0 2 IF STALLING OCCURS DISABLE THE HUNTING , PREVENTION FUNCTION (C 7- 0 1=0) IF HIGH RESPONSIVENESS IS MORE IMPORTANT THAN SUPPRESSING OSCILLATION.

No comments