MOTOR 2 RATED SLIP AND MOTOR 2 NO LOAD CURRENT OF INVERTER




MOTOR 2 RATED SLIP.

to set the motor ,s rated slip in unit of Hz .
note: factory setting depends on the capacity of the inverter ,the table is the value of inverter for 0 , . 4 kw and 200 v . to calculate the value showed on the nameplate of the motor and set the value . motor,s rated slip = motor,s rated frequency rated x the number of speed motor,s poles/120 .





MOTOR 2 NO LOAD  CURRENT .

to set motor 2,s zero load current in unit of a .
note : please set the zero load current when the motor is  at rated voltage and rated frequency , normally there is on record on the nameplate of the motor please Enquire from the factory.
to set the number of the motor ,s poles . please set it according to the record on the motor,s nameplate.