WINNER INVERTER,S MODEL WIN-VA-3R7T4 (UP COMMAND SETTING 10 / DOWN COMMAND SETTING 11.



It is the function to control the inverter,s output frequency through the control terminal,s on/off . when using this function please make sure to set the 2 multi function input up/down command .if only to set single multifunction input the fault ope 03 will occur .besides in the occasion where acceleration /deceleration stop was both set (value a) ope 03 fault will occur too. b1-02  operation method selection  please set it to be 1 (exterior terminal ) it won,t act except when it is set 1 . frequency ,s up/down to mimes or plus the time normally )c1-01 ~08 ).
frequency up/down . when up/down , output frequency ,s upper limit and lower limit will be set as follows ,upper limit , maximum output frequency (e1-04) output frequency upper limit (d2-01)/100 .
lower limit maximum output frequency ( e1-04) output frequency command (current ) terminal 14 are input as used as frequency command input the maximum frequency value will be taken as the lower limit ,(up , down are both on /off status except that the operation command is on ) . when up/down function is used once the operation command is input the output frequency will be accelerated till it teaches the lower limit .  when up/down function and job frequency selection is selected at multi function input at the same time jog frequency option on has the priority  to be selected  .