WINNER INVERTER,S MODEL WIN-VA-3R7T4 MOTOR SWITCH COMMAND (2 MOTOR OPTIONS ) SETTING 16



CLOSED OPERATE ACCORDING TO MOTOR 2.
set one of the constant amount h1-01 ~06 (multi function  input ) to be 16 (motor 2 selection command ) the action will be open or closed by input signal . and the inverter interior memorized control modes /f characteristics motor constants can be changed . set one of the constant among h2-01 ~03 (multi function output )to be 1 c (motor selection monitoring ) and then multi -function output terminal can monitor the current motor selection  status .
please set the environment setting  constant ,cancel level a1-01 to be 3 (basic ) or 4 (ADVANCED) the following constants will be replaced according to motor 2 selection ( switching) command .
NOTE; following the switching of the motors, the below constants will be initialized when A1 -02 in not equal to  E3 -01; b3-01 ,b3-02 ,c3-01,c3-02,c4-02,c5-01,c5-02 ,c5-03,c5-04,e1-04,e4-01,e1-05,e1-06,e4-03,e1-07,e4-04,e1-08,e4-05,1-09,e4-06,e1-10,e4-06,f1-09.
please find below for the time sequence of operation  when switching from motor 1 to motor 2.