440 VOLT DC/AC WINNER INVERTER,S MULTI-STEP COMMAND 1~3/JOG FREQUENCY SELECTION (SETTING 3~6)






Win - va/vb can use 8 frequency command and 1 jog frequency command . hence the maximum number of speed steps is 9 .
To switch between these frequency command  please set the multi function input to be multi step speed command 1-3 and jog frequency selection .




Terminal
No
Setting value
Description
            5
    H1-03
     3
Multi-speed command 1(when setting the auxiliary frequency command in h3-05 , it is also used for the switch between main speed/auxiliary speed)
            6
     H1-04
     4
Multi speed command2
            7
     H1-05
     5
Multi speed command3
            8
     H1-06
     6
Jog frequency selection (prior to multi- speed command )



as shown in below table frequency is selected according to the on/off of multi step speed command 1~3 and jog frequency selection .