ELECTRIC THREE PHASE INVERTER,S CONSTANTS DESCRIPTION .



setting value 30 function is torque limit (current limit)( on ,in current limit ).
setting value 31 function is in speed limit ( on , in speed limit ) .
setting value 33 function is zero servo is over ( on , zero servo is over ) .
setting value  37 function is in operation  2 ( on , inverter outputs frequency off : base is locked , brake by dc excite initially inverter stops ) .

Setting parameters .
Regarding the below function , please refer to the related section .
setting value 2 function is frequency (speed ) conformity 1, and reference project is constant L[the setting of frequency detection function :L4-01~05] .
setting value 3 function is any frequency ( speed ) conformity 1 , and reference project is constant L[the setting of frequency detection function :L4-01~05] .
setting value 4 function is frequency ( fout ) detection 1> ,  and reference project is constant L[the setting of frequency detection function :L4-01~05] .
setting value 5 function is frequency ( fout ) 2 < ,  and reference project is constant L[the setting of frequency detection function :L4-01~05] .
setting value b function is torque detection no , and reference project is constant L [ the setting of over torque detection function : L6-01 ~06 ]  .
setting value c function is frequency command missing , and reference project is constant L[ the setting of timing function : b4-01 ~ 02 ] .
setting value 12 function is timing function output , and reference project is constant L[ the setting of timing function : b4-01 ~ 02 ] .
setting value 13 function is frequency ( speed ) conformity 2 , and reference project is content L[the setting of frequency detection :L4-01~05] .
setting value 14 function is any frequency ( speed ) conformity 2 ,and reference project is content L[the setting of frequency detection :L4-01~05] .
setting value 15 function is frequency  ( fout ) detection 3 > ,and reference project is content L[the setting of frequency detection :L4-01~05] .
setting value 16 function is frequency ( fout ) detection 4 < , and reference project is content L[the setting of frequency detection :L4-01~05] .
setting value 17 function is over torque detection 1 nc , and constant L [ the setting of over torque detection function : L 6 -01 ~ 06 ].
setting value 18 function is over torque detection 2 no , and constant L [ the setting of over torque detection function : L 6 -01 ~ 06 ].
setting value 19 function is over torque detection 2 nc ,  and constant L [ the setting of over torque detection function : L 6 -01 ~ 06 ].

Regarding the below function , please refer to the function table of multifunctional output .

setting 6 function , inverter is ready for preparation .
setting 7 function is in low - voltage ( uv ) detection of main circuit .
setting 8 function is in base locking .
setting 9 function is frequency command selection status .
setting A function is operation command selection status .
setting D function is malfunction of braking resister .
setting E function is fault .
setting 10 function is minus fault .
setting 11 function is in fault reset .
setting 1A function is in reverse operation .
setting 1B function is base locking 2 .
setting 1D function is in regeneration operation .
setting 1E function is fault reset retry .
setting 30 function is in torque limit ( current  limit ).
setting 31 function is in speed limit .

In operation  ( setting :0 ) .
off = operation command is off and there is output voltage .
on = there is voltage output either when operation command is on or off .

Zero speed ( setting " 0)
off = maximum output frequency shall be lower than output frequency ( e1-09 ) [ vector control with pg motor speed is higher than zero - speed level ( b2-01 )].
on = output frequency is lower than output frequency ( e1=09)[vector control with pg motor speed is bigger than zero - speed level (b2-01) ] .